A Comparative Study of the Measurement of Mean Arterial Blood Pressure Using Automatic Oscillometers, Arterial Cannulation and Auscultation

Abstract

Mean brachial artery pressures determined by five different non-invasive automatic oscillometric and one auscultatory preferred (oscillometric back-up) blood pressure (BP) monitors were compared with mean arterial pressures (MAP) obtained by cannulation of the radial artery of the same arm. The devices tested all performed similarly, showing a wide range of variation (+40% to −29%) compared with the directly measured MAP, and all tended to over-read at low values and under-read at high values. Trend information was generally acceptable, but occasionally was misleading. In addition, using one of the devices, systolic and diastolic blood pressure measurements were compared with those obtained by auscultation. This gives a range of differences from +22 to −25 mmHg for systolic and +20 to −12 mmHg for diastolic BP measurements. (The average fell within 1.0 mmHg of the auscultatory measurement, with a standard deviation of 10 mmHg.) Thus, the automatic oscillometric BP monitors tested were comparable in accuracy to auscultatory BP measurement, and are satisfactory for routine use in the appropriate clinical context. However, in settings where significance is to be attached to individual BP readings rather than to trends, or where a high degree of accuracy is required, automatic oscillometric machines cannot be regarded as satisfactory alternatives to arterial cannulation.

References

1. Amaranath L., Burke P., Kreul J., Kirilcuk F., Gravenstein J.S. Why monitor? In: Gravenslein J.S., Newbower R.S., Ream A.K., Smith N.T., Barden J eds. Monitoring Surgical Patients in the Operating Room. Thomas, Springfield 1979.
2. Van Bergen F.H., Weatherhead D.S., Treloar A.E., Doblein A.B., Buckley J.J. Comparison of indirect and direct methods of measuring arterial blood pressure. Circulation 1954; 10: 481–490.
3. Berliner K., Fujiy H., Ho Lee D., Yildiz M., Gamier B. The accuracy of blood pressure determinations. A comparison of direct and indirect measurements. Cardiologia 1960; 37: 118–128.
4. Cohn J.N. Blood pressure measurement in shock. JAMA 1967; 199: 972–976.
5. Geddes L.A. The direct and indirect measurement of blood pressure. Year Book Medical Publishers Inc, Chicago 1970; 46–66.
6. Runciman W.B., Rutten A.J., Ilsley A.H. An evaluation of blood pressure measurement. Anaesth Intens Care 1981; 9: 314–325.
7. Gardner R.M. Direct blood pressure measurement — dynamic response requirements. Anesthesiology 1981; 54: 227–236.
8. Ramsey M. Non-invasive automatic determination of mean arterial pressure. Med Biol Eng Comput 1979; 17: 11–18.
9. Gravlee G.P., Pauca A.L., Cordell A.R., Mills S.A., Hudspeth A.S. Comparison of brachial, radial and aortic arterial pressure monitoring during cardiac surgery. Anesthesiology 1984; 61, 3A: A69.
10. Sy W.P. Ulnar nerve palsy possibly related to use of automatically cycled blood pressure cuff. Anesthesia and Analgesia 1981; 60: 687–688.
11. Hutton P., Dye J., Prys-Roberts C. An assessment of the Dinamap 845. Anaesthesia 1984; 39: 261–267.

Cite article

Cite article

Cite article

OR

Download to reference manager

If you have citation software installed, you can download article citation data to the citation manager of your choice

Share options

Share

Share this article

Share with email
EMAIL ARTICLE LINK
Share on social media

Share access to this article

Sharing links are not relevant where the article is open access and not available if you do not have a subscription.

For more information view the Sage Journals article sharing page.

Information, rights and permissions

Information

Published In

Article first published: February 1986
Issue published: February 1986

Keywords

  1. MEASUREMENT: monitoring
  2. blood pressure
  3. automatic blood pressure monitors
  4. arterial cannulation
  5. oscillometry
  6. auscultation

Rights and permissions

© 1986 Australian Society of Anaesthetists.
Request permissions for this article.
PubMed: 3954015

Authors

Affiliations

A. J. Rutten, B.Sc.
Department of Anaesthesia and Intensive Care, Flinders Medical Centre, The Flinders University of South Australia, Adelaide, South Australia
Hospital Scientist.
A. H. Ilsley, Ph.D.
Department of Anaesthesia and Intensive Care, Flinders Medical Centre, The Flinders University of South Australia, Adelaide, South Australia
Principal Hospital Scientist, Lecturer.
G. A. Skowronski, M.B.B.S.(Hons.), M.R.C.P.(U.K.), F.R.A.C.P.
Department of Anaesthesia and Intensive Care, Flinders Medical Centre, The Flinders University of South Australia, Adelaide, South Australia
W. B. Runciman, B.Sc.(Med.), M.B.B.Ch., F.F.A.R.A.C.S., Ph.D.
Department of Anaesthesia and Intensive Care, Flinders Medical Centre, The Flinders University of South Australia, Adelaide, South Australia

Metrics and citations

Metrics

Journals metrics

This article was published in Anaesthesia and Intensive Care.

VIEW ALL JOURNAL METRICS

Article usage*

Total views and downloads: 424

*Article usage tracking started in December 2016


Altmetric

See the impact this article is making through the number of times it’s been read, and the Altmetric Score.
Learn more about the Altmetric Scores



Articles citing this one

Receive email alerts when this article is cited

Web of Science: 43 view articles Opens in new tab

Crossref: 56

  1. Manual and Oscillometric Blood Pressure in tPA‐Treated Acute Ischemic ...
    Go to citation Crossref Google Scholar
  2. Cohort Studies, Meta-analyses, and Clinical Trials in Childhood Hypert...
    Go to citation Crossref Google Scholar
  3. Cohort Studies, Meta-analyses, and Clinical Trials in Childhood Hypert...
    Go to citation Crossref Google Scholar
  4. A performance comparison of the most commonly used minimally invasive ...
    Go to citation Crossref Google Scholar
  5. Hemodynamic Monitoring
    Go to citation Crossref Google Scholar
  6. Comparison between invasive and noninvasive blood pressure measurement...
    Go to citation Crossref Google Scholar
  7. Regional Anesthesia Safety
    Go to citation Crossref Google Scholar
  8. Comparison of Continuous Noninvasive Blood Pressure Monitoring by TL-3...
    Go to citation Crossref Google Scholar
  9. The accuracy of blood pressure measured by arterial line and non-invas...
    Go to citation Crossref Google Scholar
  10. Transport of critically ill patients
    Go to citation Crossref Google Scholar
  11. Clinical Nurse Specialists Leading Research to Improve Practice in the...
    Go to citation Crossref Google Scholar
  12. Noninvasive Techniques for Blood Pressure Measurement Are Not a Reliab...
    Go to citation Crossref Google Scholar
  13. Blood Pressure Monitoring
    Go to citation Crossref Google Scholar
  14. Comparison of non‐invasive and invasive blood pressure in aeromedical ...
    Go to citation Crossref Google Scholar
  15. Which pressure to believe? A comparison of direct arterial with indire...
    Go to citation Crossref Google Scholar
  16. The principles of aeromedical retrieval of the critically ill
    Go to citation Crossref Google Scholar
  17. A poor correlation exists between oscillometric and radial arterial bl...
    Go to citation Crossref Google Scholar
  18. Transport of the critically ill
    Go to citation Crossref Google Scholar
  19. The Validity and Reliability of Automated and Manually Measured Toe Bl...
    Go to citation Crossref Google Scholar
  20. The Impact of Arm Position on the Measurement of Orthostatic Blood Pre...
    Go to citation Crossref Google Scholar
  21. An evaluation of the T‐Line ® Tensymeter c...
    Go to citation Crossref Google Scholar
  22. Regional AnesthesiaSafety
    Go to citation Crossref Google Scholar
  23. Comparison of the cardiopulmonary effects of anesthesia maintained by ...
    Go to citation Crossref Google Scholar
  24. Testing the Reliability of a New Ultrasonic Cardiac Output Monitor, th...
    Go to citation Crossref Google Scholar
  25. Monitoring equipment for endoscopy
    Go to citation Crossref Google Scholar
  26. The effect of differences in measurement procedure on the comparabilit...
    Go to citation Crossref Google Scholar
  27. Noninvasive Blood Pressure Monitoring
    Go to citation Crossref Google Scholar
  28. How invasive should one go?
    Go to citation Crossref Google Scholar
  29. Mobile intensive care services in rural South Australia
    Go to citation Crossref Google Scholar
  30. Theoretical analysis of non-invasive oscillometric maximum amplitude a...
    Go to citation Crossref Google Scholar
  31. Out-of-Hospital Use of a Pulse Oximeter to Determine Systolic Blood Pr...
    Go to citation Crossref Google Scholar
  32. Accuracy of oscillometric blood pressure measurement in critically ill...
    Go to citation Crossref Google Scholar
  33. Technology Assessment Status Evaluation—Monitoring Equipment For Endos...
    Go to citation Crossref Google Scholar
  34. Indirect blood pressure measurement using the Riva Rocci Korotkoff met...
    Go to citation Crossref Google Scholar
  35. Noninvasive continuous blood pressure measurement during anaesthesia: ...
    Go to citation Crossref Google Scholar
  36. Comparison of the sphygmooscillographic method with the direct and aus...
    Go to citation Crossref Google Scholar
  37. External Abdominal Aortic Compression: A Study of a Resuscitation Mano...
    Go to citation Crossref Google ScholarPub Med
  38. MONITORING THE PERIPHERAL VASCULAR SYSTEM
    Go to citation Crossref Google Scholar
  39. Comparison of intraarterial with continuous noninvasive blood pressure...
    Go to citation Crossref Google Scholar
  40. Errors, Incidents and Accidents in Anaesthetic Practice
    Go to citation Crossref Google ScholarPub Med
  41. Blood Pressure Monitoring—Applications and Limitations: An Analysis of...
    Go to citation Crossref Google ScholarPub Med
  42. Autonomic nervous system function in severe breath-holding spells
    Go to citation Crossref Google Scholar
  43. The Dinamap 1846SX automated blood pressure recorder: comparison with ...
    Go to citation Crossref Google Scholar
  44. Bedside Catheterization
    Go to citation Crossref Google Scholar
  45. The Effect of the Depth of Neuromuscular Blockade on the Haemodynamic ...
    Go to citation Crossref Google ScholarPub Med
  46. The relative accuracies of two automated noninvasive arterial pressure...
    Go to citation Crossref Google Scholar
  47. Accuracy of four indirect methods of blood pressure measurement, with ...
    Go to citation Crossref Google Scholar
  48. Monitoring Epidural Analgesia in the Parturient
    Go to citation Crossref Google ScholarPub Med
  49. Blood pressure measurement during transport A comparison of direct and...
    Go to citation Crossref Google Scholar
  50. Routine Monitoring of Critically I11 Patients
    Go to citation Crossref Google Scholar
  51. How reliable are indirect blood pressure measurement devices in the in...
    Go to citation Crossref Google Scholar
  52. Monitoring in emergency medicine
    Go to citation Crossref Google Scholar
  53. Noninvasive Blood Pressure Measurement
    Go to citation Crossref Google Scholar
  54. Accuracy of blood pressure measurements made aboard helicopters
    Go to citation Crossref Google Scholar
  55. The pathophysiology of shock ∗
    Go to citation Crossref Google Scholar
  56. Systemic Arterial Blood Pressure
    Go to citation Crossref Google ScholarPub Med

Figures and tables

Figures & Media

Tables

View Options

View options

PDF/ePub

View PDF/ePub

Get access

Access options

If you have access to journal content via a personal subscription, university, library, employer or society, select from the options below:

ASA and NZSA members can access this journal content using society membership credentials.

ASA and NZSA members can access this journal content using society membership credentials.


Alternatively, view purchase options below:

Purchase 24 hour online access to view and download content.

Access journal content via a DeepDyve subscription or find out more about this option.