Volume 15, Issue 10 p. 2371-2379
Free Access

Physical Activity Assessment With Accelerometers: An Evaluation Against Doubly Labeled Water

Guy Plasqui

Guy Plasqui

Department of Biomedical Science, University of Wollongong, Wollongong, Australia

Search for more papers by this author
Klaas R. Westerterp

Corresponding Author

Klaas R. Westerterp

Department of Human Biology, Maastricht University, Maastricht, The Netherlands

Department of Human Biology, University of Maastricht, PO Box 616, 6200MD Maastricht, The Netherlands. E-mail: [email protected]Search for more papers by this author
First published: 06 September 2012
Citations: 437

The costs of publication of this article were defrayed, in part, by the payment of page charges. This article must, therefore, be hereby marked “advertisement” in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.

Abstract

This review focuses on the ability of different accelerometers to assess daily physical activity as compared with the doubly labeled water (DLW) technique, which is considered the gold standard for measuring energy expenditure under free-living conditions. The PubMed Central database (U.S. NIH free digital archive of biomedical and life sciences journal literature) was searched using the following key words: doubly or double labeled or labeled water in combination with accelerometer, accelerometry, motion sensor, or activity monitor. In total, 41 articles were identified, and screening the articles’ references resulted in one extra article. Of these, 28 contained sufficient and new data. Eight different accelerometers were identified: 3 uniaxial (the Lifecorder, the Caltrac, and the CSA/MTI/Actigraph), one biaxial (the Actiwatch AW16), 2 triaxial (the Tritrac-R3D and the Tracmor), one device based on two position sensors and two motion sensors (ActiReg), and the foot-ground contact pedometer. Many studies showed poor results. Only a few mentioned partial correlations for accelerometer counts or the increase in R2 caused by the accelerometer. The correlation between the two methods was often driven by subject characteristics such as body weight. In addition, standard errors or limits of agreement were often large or not presented. The CSA/MTI/Actigraph and the Tracmor were the two most extensively validated accelerometers. The best results were found for the Tracmor; however, this accelerometer is not yet commercially available. Of those commercially available, only the CSA/MTI/Actigraph has been proven to correlate reasonably with DLW-derived energy expenditure.

Introduction

A sedentary lifestyle, often adopted during adolescence and continued in adulthood, is a major concern for public health. Whereas at the age of nine, 97% of children of a European population meet the activity recommendations, only 82% of the boys and 62% of the girls meet these recommendations at the age of 15 (1). Individuals who are regularly physically active enjoy better health and have a greater degree of independence than those who are sedentary (2). Low levels of physical activity are associated with several diseases, such as cardiovascular disease (3, 4), diabetes mellitus type II (5, 6, 7, 8), osteoporosis (9, 10), obesity (11, 12, 13), and some cancers such as colon or breast cancer (14). The dramatic increase in the prevalence of overweight and obesity over the past decades (15, 16, 17) is related to, and often ascribed to, lower levels of physical activity (13).

Physical activity (PA)1 can be defined as body movement, produced by skeletal muscles, resulting in energy expenditure (18). It is a complex behavior, including sports as well as non-sports activities. Sports are often planned, structured, and repetitive, with the objective of improving or maintaining physical fitness (18), whereas non-sports activities can be subdivided into different categories such as occupational, leisure-time, and household activities but also personal care and transportation. From this definition, it is clear that PA has an impact on energy expenditure, and the extent to which body movement leads to energy expenditure is dependent on body size and body composition.

The complex nature of PA makes it difficult to accurately measure all of its aspects and assess the impact on outcome parameters, such as energy expenditure. Different measuring techniques available can be grouped into five categories: behavioral observation, self-report (questionnaires and activity diaries), physiological markers (heart rate, body temperature, ventilation), motion sensors (pedometers, accelerometers), and indirect calorimetry (19, 20, 21). Ideally, PA should be assessed during daily life, over periods long enough to be representative of the habitual activity level and with minimal discomfort to the subject. Furthermore, it is important to identify PA patterns (frequency, duration, intensity) as well as activity-related energy expenditure.

This review will focus on the ability of different accelerometers to assess daily PA as compared with the doubly labeled water (DLW) technique, which is considered the gold standard for measuring energy expenditure under free-living conditions.

Activity-related Energy Expenditure and the PA Level (PAL)

By combining a measurement of total energy expenditure (TEE) by means of DLW with basal metabolic rate (BMR) by a ventilated hood [or sleeping metabolic rate (SMR)with a respiration chamber], activity-related energy expenditure (AEE) can be calculated as: AEE = (0.9 × TEE) − BMR. This calculation assumes diet-induced thermogenesis to be 10% of TEE. Another common way to convert energy expenditure to the PAL is the expression of TEE as a multiple of BMR, PAL = TEE × BMR−1.

Since the DLW technique is expensive, this method is used most often in small study populations. Furthermore, this technique provides an accurate measure of TEE, but no information on PA patterns in terms of frequency, duration, and intensity is available. It is, however, the only method available to accurately measure TEE under free-living conditions and is, therefore, considered to be the gold standard for the measurement of energy expenditure (EE) during daily life.

Accelerometry

Motion sensors are probably the oldest tools available to measure body movement or PA. They have evolved from mechanical pedometers to electronic uniaxial and triaxial accelerometers. The first pedometer was probably invented by Leonardo da Vinci, ∼500 years ago (22). It was designed to count steps by responding to vertical acceleration, moving a lever arm up and down, resulting in rotation of a gear. Another mechanical motion sensor, the actometer, was developed by Schulman and Reisman (23). They used a modified wristwatch to transform vertical accelerations into rotation of an internal rotor. Movement of the rotor is then registered as a change in position of the clock hands, and the resulting change in time displayed is used as the activity measure (24). In the 1970s, the electronic large-scale integrated motor activity monitor was developed (25). The device is slightly larger than a wristwatch and can be worn at various body locations. The sensor consists of a cylinder containing a ball of mercury. Tilting of the instrument causes the ball of mercury to roll down the cylinder, making contact with a mercury switch at the end of the cylinder. The number of closures of the mercury switch is recorded and used as a measure of PA (25).

Currently, several electronic pedometers are commercially available (26). Pedometers can be used to count steps and, when the step length is known, walking distance and thus provide information about total walking and/or running activity. Since only the total amount of steps is monitored, there is no information on frequency, duration, and intensity of PA (27). Because of the complex nature of different activities in daily life, the applicability of pedometers to assess free-living activity is limited.

Accelerometers are electronic motion sensors that consist of piezo-resistive or piezo-electric sensors. Piezo-resistive accelerometers respond to accelerations by a change in resistance of silicon resistors, which is then transformed to a voltage proportional to the amplitude and frequency of the acceleration of the small mass in the sensor. Piezo-resistive accelerometers require an external power source and also respond to a constant acceleration such as gravity (28). Piezo-electric accelerometers generate an electric charge in response to a mechanical force, thus, acceleration (28). They do not respond to constant acceleration, and their major advantage is that no power supply is required, except for data storage, resulting in a considerable reduction in size and weight of the device.

Over the past decades, advances in technology have resulted in the development of small and light instruments that are able to collect data at a high-frequency and store minute-by-minute data over several days or weeks. Uniaxial accelerometers measure accelerations in one direction, usually in the vertical plane, whereas triaxial accelerometers measure accelerations in the anteroposterior, mediolateral, and vertical direction. With the wide range of activities a subject can perform, triaxial accelerometers provide more information and show a better relationship to AEE than uniaxial (29).

Ideally, an accelerometer should be small, light, unobtrusive, sensitive within the right frequencies and amplitudes, and able to store data over long periods of time. The size of the device is important in order not to interfere with normal daily activity patterns. Bouten et al. have summarized the frequency and amplitude range required to accurately measure human movement (28). For accelerometers placed at waist level, a frequency band between 0.3 and 3.5 Hz and an amplitude range of −6 g to 6 g should suffice to capture daily PA. Within these ranges, accelerations during low-intensity activities, such as sedentary activities or walking, as well as high-intensity activities or exercise, such as running and jumping, can be measured (28). Low- and high-pass filters can be used to eliminate those frequencies that are unlikely to arise from human movement, such as high frequencies due to transportation.

To test the capability of accelerometers to predict EE, validation against indirect calorimetry is necessary. Many accelerometers have been tested under laboratory conditions during standardized activities (29, 30, 31, 32, 33, 34), in field settings against portable calorimeters (35, 36), or in the controlled environment of a whole room calorimeter (37, 38, 39). Most accelerometers show good to very good correlations (r = 0.74 to 0.95) with EE during walking and running on a treadmill or with other defined activities (29, 31, 32, 33, 34). An increasing number of accelerometers have also been validated against DLW under unconfined conditions in daily life. The purpose of this review is to compare the ability of the different accelerometers to accurately assess daily PA.

Research Methods and Procedures

The PubMed Central database (U.S. NIH free digital archive of biomedical and life sciences journal literature) was searched using the following key words: doubly or double labeled or labeled water in combination with accelerometer, accelerometry, motion sensor, or activity monitor. In total, 41 articles were identified, and screening the articles’ references resulted in one extra article. One article was excluded because it was written in French (40), and 13 more articles were excluded because they contained no data about accelerometry or DLW, contained no new data, or the primary aim was not to compare both methods and, hence, no correlations or mean differences between methods were provided (19, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50, 51, 52).

Results

Eight different accelerometers were identified, three uniaxial, one biaxial, two triaxial, a device based on two position sensors and two motion sensors (ActiReg), and a foot-ground contact pedometer. The Lifecorder (Suzuken Co., Japan) is a uniaxial accelerometer (62 × 46 × 26 mm; 42 g) detecting accelerations along the vertical axis. Before use, the accelerometer is programmed with age, gender, height, and body weight, and PA is expressed as the energy spent on activity in kilocalories (53). The Actigraph/CSA/MTI (first known as CSA, Computer Science Applications model 7164; later known as MTI, Manufacturing Technology Inc., Fort Walton Beach, FL; now known as Actigraph, Health One Technology, Fort Walton Beach, FL) is a small, lightweight, uniaxial accelerometer detecting accelerations from 0.05 to 2 g (54). The Caltrac (Muscle Dynamics Fitness network, Torrance, CA) is a uniaxial accelerometer that has a ceramic piezo-electric transducer that detects vertical displacement. The signal is translated into a total activity energy count per day (55). The Actiwatch AW16 (Minimitter Co., Inc.) is a small (28 × 27 × 10 mm), lightweight (16 g), biaxial accelerometer (56). Activity is measured by means of a piezo-electric accelerometer that is set up to record the integration of intensity, amount, and duration of movement (56). The Tritrac-R3D (Professional Products, Madison, WI) is a triaxial accelerometer providing minute-by-minute activity counts for the anteroposterior (X), mediolateral (Y), and vertical (Z) direction, as well as the vector magnitude calculated as √(X2 + Y2 + Z2) (57). The Tracmor (Philips Research, Eindhoven, The Netherlands) is a triaxial accelerometer containing three uniaxial piezo-electric accelerometers. It measures 72 × 26 × 7 mm and weighs 22 g (battery included). Accelerometer output (counts) represents the rectified and integrated acceleration signal, stored minute by minute for each axis, X (mediolateral), Y (longitudinal or vertical), and Z (anteroposterior), separately (58). The Tracmor is not yet commercially available. The ActiReg (PreMed AS, Oslo, Norway) has two body position sensors (tilt switches) and two motion sensors connected by cables to a battery-operated storage unit (85 × 45 × 15 mm, 60 g) that is fixed to an elastic belt worn around the waist. Energy expenditure is calculated from the identification of different body positions and motions multiplied by literature values for the energy costs of different activities (59). The foot-ground contact pedometer (Fitsense Technology Inc., Southboro, MA) is a small electronic device (∼5.8 cm × 7.6 cm × 6.4 cm; 56 g) that fits into a cloth pouch mounted to the outside of the boot or shoe through the shoelaces. The monitor measures the foot-ground contact time and classifies activities as run, walk, non-exercise activity, or no activity by the pattern of the foot-ground contact waveforms (60).

Table 1 summarizes the results of all of the identified studies. For every study, the dependent and independent variables are given, as well as correlations and partial correlations when provided. Some studies only mentioned mean differences between DLW-derived EE and calculated EE based on the activity monitor and subjects’ characteristics. For two studies, the increase in R caused by the activity counts is mentioned.

Table 1. . Observed correlations, partial correlations, and mean differences between doubly labeled water (DLW)-derived energy expenditure measures and accelerometry to assess physical activity
Subjects Monitor (location) Accelerometer worn (days) DLW (days) BMR or SMR Dependent variable Independent variable R Partial R Difference (DLW − accelerometer) (mean ± 2 SD) (MJ/d) Reference
72 healthy women Actigraph (NP) 14 14 C AEE AC 0.30 (54)
18 female students ActiReg (chest and thigh) 10 10 M TEE TEEAR NP 0.41 ± 2.69 (59)
13 COPD patients ActiReg (chest and thigh) 7 7 M TEE TEEAR 0.09 ± 0.78 (64)
BMR, AEEAR 0.82 Rincrease 0.40
29 children (4–6 years) Actiwatch (ankle) 8 8 - TEE AC 0.27NS (68)
FFM, AC 0.52 NS
31 children Caltrac (hip) 3 14 M AEE AC −0.09NS (69)
35 elderly women Caltrac (waist) 9 10 M AEE AEECaltrac NP 2.06 ± 1.75 (55)
32 elderly men AEE AEECaltrac NP 2.74 ± 3.15
20 overweight women Caltrac (waist) 5 14 M TEE BM, height, age, gender, AC <0.26NS NP −0.08 ± 1.63 (70)
22 older claudicants Caltrac M AEE AEEcaltrac 0.83 0.49 (SD; NP) (71)
26 children CSA (lower back) 14 14 C PAL AC 0.58 (72)
AEE sex, AC 0.67 NP
TEE sex, BM, AC 0.77 NP
25 adolescents CSA (lower back) 10–14 10–14 M and C AEE × BM−1 AC 0.69 (73)
7 adolescent speed skaters CSA (lower back) 10 10 M AEE × BM−1 AC 0.96* (74)
PAL AC 0.96*
24 healthy Swedish women CSA (NP) 14 14 C TEE TEEcalc NP 0.025 ±2.72 (75)
136 black and Hispanic women CSA (hip) 7 7 M TEE BM, AC 0.62 0.26 (76)
FFM, AC 0.66 0.18
AEE BM, AC 0.30 0.23
FFM, AC 0.35 0.20
34 healthy women CSA (waist) 11–14 14 M TEE TEEaccel NP 0.37 ± 2.93 (77)
104 Scottish children CSA/MTI (hip) 3–10 7–10 C PAL AC 0.33 (78)
8 male marines Foot-ground contact pedometer (shoe) 2 2 C TEE TEEPEDO 0.17NS 0.02 ± 3.66 (67)
AEE AEEPEDO 0.23NS 0.02 (SD; NP)
7 male and 10 female sailors Foot-ground contact pedometer (shoe) 8 8 C TEE TEEPEDO 0.89 0.39 ± 3.42 (60)
24 Japanese men Lifecorder (waist) 14 14 M TEE TEE from age, sex, height, BM, AC 0.83 NP 2.37 ± 1.87 (53)
40 healthy Japanese men Lifecorder (waist) 14 14 M TEE FFM, high-intensity EPA 0.72 Rincrease 0.25 (79)
36 adolescents MTI (lower back) 14 14 M AEE × BM−1 AC 0.51 (80)
PAL AC 0.40
ArteEE ArteACC 0.68
30 adults Tracmor (lower back) 7 7 M PAL AC 0.73 (81)
AEE × BM−1 AC 0.63
28 elderly Tracmor (lower back) 14 14 M PAL AC 0.78 (82)
11 children Tracmor (lower back) 14 14 M PAL AC 0.79 (83)
29 adults Tracmor (lower back) 15 15 M TEE BM, age, height, AC 0.91 0.73 (58)
AEE BM, age, height, AC 0.90 0.79
PAL AC 0.77
12 patients with chronic low back pain Tracmor (lower back) 14 14 M PAL AC 0.72 (84)
30 adults Tracmor (lower back) 7 7 M Residual TEE vs. SMR AC 0.80 (85)
13 adult women Tritrac-R3 days (right hip) 7 7 M AEE AC (vector) 0.54NS (57)
AEEtritrac 1.34 (SD; NP)
CSA (left hip) AEE AC 0.45NS
AEE from AC, BM 2.07 (SD. NP)
47 children Tritrac-R3D (waist) 4 10 C PAL AC (vector) 0.31 (86)
AC (Y axis) 0.34
AC (Z-axis) 0.42
  • Where necessary, energy expenditure units have been converted to MJ/d and R2 values have been converted to R values to create more consistency. M, measured; C, calculated; NS, not significant; NP, not provided; —, not relevant; partial R or Rincrease, refers to specific contribution of the accelerometer to the total correlation; BMR, basal metabolic rate; SMR, sleeping metabolic rate; TEE, total energy expenditure; PAL, physical activity level (TEE × BMR−1); AEE, activity-related energy expenditure (0.9 × TEE-BMR); residual TEE vs. SMR, the residuals of the simple regression analysis with TEE as the dependent and SMR as the independent variable; AC, activity counts as measured with the accelerometer; BM, body mass; FFM, fat-free mass; TEEAR, TEE calculated from ActiReg data; AEEcaltrac, AEE as calculated by the Caltrac accelerometer; AEEtritrac, AEE as calculated by the Tritrac accelerometer; COPD, chronic obstructive pulmonary disease; CSA, Computer Science and Applications, Inc. (Shalimar, FL); MTI, Manufacturing Technology Incorporated (Fort Walton Beach, FL); Actigraph (formerly Computer Science Applications model 7164); Lifecorder (Suzujen Co., Japan); Tritrac-R3D (Hemokinetics, Madison, WI); Caltrac (Hemokinetics, Madison, WI); Tracmor (Philips Research, Eindhoven, The Netherlands); Actiwatch (activity monitor, model AW16, Minimitter Co., Inc.); high-intensity EPA, time spent in high intensity exercise physical activity (min); ArteEE (minutes/d) = [AEE (kJ/d)/reference activity (kJ/min) − BMR (kJ/min)]; ArteACC = [total daily activity counts (counts/d)/exercise activity counts (counts/min)].
  • * Correlations obtained during off-season training (mostly running). Correlations for pre-season training (mostly skating) were not significant (0.36 and 0.32 for AEE/BM and PAL, respectively).
  • TEEcalc was calculated using individual calibration curves, obtained by having subjects perform 6 standardized activities, and from BMR, calculated using prediction equations.
  • The vector magnitude is calculated as √(X2 + Y2 + Z2) where X, Y, and Z represent activity counts per minute for the anteroposterior, mediolateral, and vertical axis, respectively.

Discussion

The advantage of accelerometry is that it can provide information about the total amount, the frequency, the intensity, and the duration of PA in daily life. The advantage of DLW is that it is the only technique available to accurately measure EE in daily life over longer periods of time. Ideally, the combination of both methods should be used to gain further insight into the level of PA. However, given the high cost of DLW, the combination of DLW with accelerometry is not always possible and is rarely used for large study populations. Many studies, therefore, have been aimed at developing prediction equations, based on accelerometry and subject characteristics, to predict DLW-derived EE measures. When comparing the validity of different accelerometers, some considerations should be made. First, when multiple regression is used with subject characteristics and activity counts, many studies do not mention partial correlations for activity counts or the increase in R2 caused by the activity counts. For example, in the study of Rafamantanantsoa et al. (53), the accelerometer predicted TEE of 69% (R = 0.83, Table 1), while the calculation of TEE from the accelerometer was based on age, sex, height, body mass (BM), and activity counts and no data on the contribution of the activity counts were available. Studies using the Caltrac have the same shortcoming and should, therefore, be interpreted with care. A validation study of the Caltrac using a respiration chamber showed that Caltrac-estimated EE was, and Caltrac counts only were not, correlated with chamber-assessed EE, r = 0.81 to 0.87 (p < 0.001) and r = 0.11 to 0.14 (not significant), respectively (61). In comparison, in the study of Plasqui et al. (58), age, BM, and height alone already explained 64%, and the accelerometer (Tracmor) added 19% of the variation in TEE. Second, some studies only present the mean difference between methods after EE has been calculated using subject characteristics and accelerometer output. Again, there is no information available about whether or not the accelerometer output significantly contributed to the prediction equation. Third, to have some idea about the ability of the accelerometer to predict individual EE rather than EE on a group level only, standard errors (when using regression analysis) or limits of agreement (when using mean differences) should be presented. Fourth, various methods can be applied to correct EE for body size and composition. The simplest method is the use of ratios such as the PAL (TEE × BMR−1). Theoretically, the use of ratios is justified only when the regression line of the numerator vs. the denominator has a zero intercept. If not, the impact of a non-zero intercept is bigger at the lower range of EE. The same problem occurs when trying to correct AEE for BM or body composition. Many authors use AEE × BM−1 as a measure of PA. Prentice et al. (62) suggested using BM to the exponent of 0.5 rather than 1 as the denominator, since not all activities have the same weight-bearing impact on AEE. But they also emphasize that it is not recommended to use this as a universal approach and that there is probably no generally applicable adjustment factor. On the other hand, Schoeller et al. concluded that dividing AEE by body weight is an appropriate means of comparing the volume of PA among individuals of different body size (63). They correlated AEE, as measured during strictly standardized light activities, with BM, fat free mass (FFM), fat mass (FM), and resting metabolic rate (RMR) and found the best correlations, as well as a zero intercept, for BM. This is perhaps not surprising because 1) when AEE is used as the dependent variable, RMR is already removed from TEE; and 2) FFM is the major determinant of RMR, but once PA is performed, the effect of FM in addition to that of FFM becomes larger since FM can then be considered as extra weight to be moved. As BM includes both FFM and FM, BM was found to be a better predictor of AEE then either of the components separately. Multiple regression with both FFM and FM, however, might have resulted in an even better correlation, since both contribute to AEE to a different extent (58). Therefore, the use of regression analysis is probably the most appropriate approach. Both BM and gender or, when data on body composition are available, both FM and FFM can be entered as independent variables. Finally, methodological differences in the study designs could affect the outcomes. The location of the monitor on the body varies. The observation period of the accelerometer and DLW should always coincide. There might also be differences in the standard operating procedure for DLW among laboratories. Basal or sleeping metabolic rate can be measured or calculated. The level of PA, as well as the range in PALs, differ among populations and can influence the results. For example, in the study of Arvidsson et al., the EE assessed using the ActiReg shows good agreement with DLW, but the authors correctly conclude that this applies to a population with a low PAL (i.e., patients with chronic obstructive pulmonary disease, average PAL 1.51) (64). Another study with the ActiReg in female students with higher PALs (average PAL 1.71) showed much poorer results (59). All of these factors complicate the comparison among studies and different accelerometers and should be taken into account when interpreting the results presented in Table 1.

Of the uniaxial accelerometers, the Actigraph or CSA/MTI is the only commercially available accelerometer that has repeatedly been shown to significantly correlate with DLW-derived EE. Actiwatch counts did not significantly correlate with TEE. None of the studies using the Caltrac showed good correlations for activity counts and EE, and high mean differences were reported between measured and calculated EE. No partial correlations for activity counts were mentioned for the Lifecorder, but one study showed a significant increase in R when time spent in high-intensity exercise, as determined by the accelerometer, was used. The Tritrac-R3D did not correlate with AEE in a small sample of 13 women, but the lack of significance might be due to the small sample size and the fact that no correction for body size was made. Another study, using the Tritrac-R3D in a group of children, showed significant correlations between PAL and activity counts when either the total vector, the Y-axis, or the Z-axis was used. The only other triaxial accelerometer validated is the Tracmor. Correlations between activity counts and EE for various versions of this accelerometer range between 0.63 and 0.80.

Ideally, prediction equations should also be validated in a cross-validation group. Because of the low number of subjects in most studies, however, a problem inherent to the use of DLW, this is usually not possible.

Recently, devices other than standard accelerometers have been developed, such as the ActiReg (59) and the Intelligent Device for Energy Expenditure and Activity (65, 66), that use multiple sensors to assess both body posture and body movement, which are then translated into EE. The ActiReg-calculated TEE did not significantly differ from DLW-measured TEE on a group level, but the individual variation in the difference between both methods was large. Furthermore, the ActiReg underestimated TEE to a greater extent at higher levels of EE (>11 MJ/d) (59). The Intelligent Device for Energy Expenditure and Activity showed good results under laboratory conditions but has not been validated against DLW. These devices require multiple sensors to be attached to the body and have a relatively large data acquisition unit, thereby diminishing wearing comfort. So far, they have not been proven to be superior in the estimation of EE to simpler accelerometers, and further research is required to determine their effectiveness as a measure of daily life EE. The foot-ground contact pedometer is also accelerometry-based but uses a different approach than standard accelerometers. It derives TEE from calculated BMR and the metabolic cost of locomotion, calculated from the foot-ground contact time and total subject weight (body weight + load) (60, 67). The mean difference between the monitor and DLW was fairly low, but the limits of agreement were large.

In summary, from Table 1 it is clear that the CSA/MTI and the Tracmor are the two most extensively validated accelerometers. The best results were found for the Tracmor; however, this accelerometer is not yet commercially available. Of those commercially available, only the CSA/MTI has been proven to correlate reasonably with DLW-derived EE. Future validation studies might consider the issues mentioned in the discussion as a guideline and provide as much information as possible on the actual contribution of the accelerometer counts to the prediction of EE.

Acknowledgments

There was no funding/outside support for this study.

Footnotes

  • 1 Nonstandard abbreviations: PA, physical activity; DLW, doubly labeled water; PAL, PA level; TEE, total energy expenditure; BMR, basal metabolic rate; SMR, sleeping metabolic rate; AEE, activity-related energy expenditure; EE, energy expenditure; BM, body mass; FFM, fat free mass; FM, fat mass; RMR, resting metabolic rate.
    • The full text of this article hosted at iucr.org is unavailable due to technical difficulties.