Stability of intravenous vitamin C solutions: a technical report

Crit Care Resusc. 2018 Sep;20(3):180-181.

Abstract

Background: There has recently been a surge of interest in intravenous (IV) vitamin C as a potential therapy in intensive care unit (ICU) patients, particularly in those with septic shock. Establishing the safety and efficacy of IV vitamin C therapy through rigorously conducted randomised controlled trials is a priority. A key logistical issue for such trials is to establish the stability of IV vitamin C solutions prepared for infusion ahead of time. Accordingly, we aimed to assess the stability of IV vitamin C solutions over time using doses of vitamin C from previous pilot trials.

Methods: We used spectrophotometry to measure the concentration of vitamin C remaining in solutions of 1.5 g per 50 mL of 0.9% saline and 2.5 g per 50 mL of dextrose 5% in water (D5W) at 0, 1, 3, 6, 9, 24, 48, 72 and 96 hours after preparation. The concentration of vitamin C in these solutions over time was assessed at 4°C in the dark and at ambient temperature and light.

Results: The concentration of vitamin C in diluted solutions was essentially unchanged over a period of 24 hours, and decreased less than 10% by 96 hours both at 4°C in the dark and at ambient temperature and light.

Conclusions: Our findings suggest that vitamin C solutions of 1.5 g per 50 mL of 0.9% saline and 2.5 g per 50 mL of D5W remain stable for up to 96 hours and do not need to be protected from light.

MeSH terms

  • Antioxidants / chemistry*
  • Ascorbic Acid / chemistry*
  • Drug Stability*
  • Humans
  • Infusions, Intravenous
  • Pharmaceutical Solutions
  • Saline Solution, Hypertonic
  • Spectrophotometry

Substances

  • Antioxidants
  • Pharmaceutical Solutions
  • Saline Solution, Hypertonic
  • Ascorbic Acid